The JMV-D double hydropneumatic unit performs the automatic start and stop system by means of adjustable pressure switches. Consisting of two MV series electric pumps connected in parallel, it allows for efficient response to flow variations. Operation is managed in cascade and with alternating start-up to ensure uniform wear of the equipment.
Technical Data
Technical Specifications
| Type | Centrais Hidropneumáticas Automáticas Duplas |
|---|---|
| Series | 2 - JMV-D (Série MV) |
| product.components | 2 Eletrobombas em paralelo |
| Protection | Proteção Digital (Falta de água, sobrecarga, falta de linha) |
| Cooling | Cooled by pumped liquid |
Série 2 (2 - JMV)
Note: Click on table rows to highlight and compare models.
| Model | kW | HP | V | Amp (A) | Head Pressure (m) | Flow Rate (l/h) |
|---|---|---|---|---|---|---|
| 2 - JMV 2-4M - D | 0.55 | 0.75 | 230 | 3.5 | 40 - 10 | 1.200 - 8.400 |
| 2 - JMV 2-5M - D | 0.55 | 0.75 | 230 | 3.5 | 50 - 12 | 1.200 - 8.400 |
| 2 - JMV 2-6M - D | 0.75 | 1 | 230 | 4.4 | 62 - 15 | 1.200 - 8.400 |
| 2 - JMV 2-7M - D | 1.1 | 1.5 | 230 | 6.3 | 74 - 18 | 1.200 - 8.400 |
| 2 - JMV 2-8M - D | 1.1 | 1.5 | 230 | 6.3 | 84 - 20 | 1.200 - 8.400 |
| 2 - JMV 2-9M - D | 1.5 | 2 | 230 | 8.4 | 95 - 23 | 1.200 - 8.400 |
| 2 - JMV 2-10M - D | 1.5 | 2 | 230 | 8.4 | 105 - 25 | 1.200 - 8.400 |
| 2 - JMV 2-11M - D | 1.5 | 2 | 230 | 8.4 | 116 - 28 | 1.200 - 8.400 |
| 2 - JMV 2-4T - D | 0.55 | 0.75 | 400 | 1.4 | 40 - 10 | 1.200 - 8.400 |
| 2 - JMV 2-5T - D | 0.55 | 0.75 | 400 | 1.4 | 50 - 12 | 1.200 - 8.400 |
| 2 - JMV 2-6T - D | 0.75 | 1 | 400 | 1.7 | 62 - 15 | 1.200 - 8.400 |
| 2 - JMV 2-7T - D | 1.1 | 1.5 | 400 | 2.4 | 74 - 18 | 1.200 - 8.400 |
| 2 - JMV 2-8T - D | 1.1 | 1.5 | 400 | 2.4 | 84 - 20 | 1.200 - 8.400 |
| 2 - JMV 2-9T - D | 1.5 | 2 | 400 | 3.2 | 95 - 23 | 1.200 - 8.400 |
| 2 - JMV 2-10T - D | 1.5 | 2 | 400 | 3.2 | 105 - 25 | 1.200 - 8.400 |
| 2 - JMV 2-11T - D | 1.5 | 2 | 400 | 3.2 | 116 - 28 | 1.200 - 8.400 |
| 2 - JMV 2-12T - D | 2.2 | 3 | 400 | 5 | 126 - 30 | 1.200 - 8.400 |
| 2 - JMV 2-13T - D | 2.2 | 3 | 400 | 5 | 137 - 33 | 1.200 - 8.400 |
Série 3 (2 - JMV)
Note: Click on table rows to highlight and compare models.
| Model | kW | HP | V | Amp (A) | Head Pressure (m) | Flow Rate (l/h) |
|---|---|---|---|---|---|---|
| 2 - JMV 3-3M - D | 0.55 | 0.75 | 230 | 3.5 | 30 - 11 | 1.200 - 9.600 |
| 2 - JMV 3-4M - D | 0.55 | 0.75 | 230 | 3.5 | 41 - 15 | 1.200 - 9.600 |
| 2 - JMV 3-5M - D | 0.75 | 1 | 230 | 4.4 | 53 - 20 | 1.200 - 9.600 |
| 2 - JMV 3-6M - D | 1.1 | 1.5 | 230 | 6.3 | 65 - 24 | 1.200 - 9.600 |
| 2 - JMV 3-7M - D | 1.1 | 1.5 | 230 | 6.3 | 76 - 28 | 1.200 - 9.600 |
| 2 - JMV 3-8M - D | 1.5 | 2 | 230 | 8.4 | 87 - 32 | 1.200 - 9.600 |
| 2 - JMV 3-9M - D | 1.5 | 2 | 230 | 8.4 | 98 - 36 | 1.200 - 9.600 |
| 2 - JMV 3-10M - D | 1.5 | 2 | 230 | 8.4 | 62 - 17 | 1.200 - 8.400 |
| 2 - JMV 3-3T - D | 0.55 | 0.75 | 400 | 1.4 | 30 - 11 | 1.200 - 9.600 |
| 2 - JMV 3-4T - D | 0.55 | 0.75 | 400 | 1.4 | 41 - 15 | 1.200 - 9.600 |
| 2 - JMV 3-5T - D | 0.75 | 1 | 400 | 1.7 | 53 - 20 | 1.200 - 9.600 |
| 2 - JMV 3-6T - D | 1.1 | 1.5 | 400 | 2.4 | 65 - 24 | 1.200 - 9.600 |
| 2 - JMV 3-7T - D | 1.1 | 1.5 | 400 | 2.4 | 76 - 28 | 1.200 - 9.600 |
| 2 - JMV 3-8T - D | 1.5 | 2 | 400 | 3.2 | 87 - 32 | 1.200 - 9.600 |
| 2 - JMV 3-9T - D | 1.5 | 2 | 400 | 3.2 | 98 - 36 | 1.200 - 9.600 |
| 2 - JMV 3-10T - D | 1.5 | 2 | 400 | 3.2 | 62 - 17 | 1.200 - 8.400 |
| 2 - JMV 3-11T - D | 2.2 | 3 | 400 | 5 | 120 - 44 | 1.200 - 9.600 |
| 2 - JMV 3-12T - D | 2.2 | 3 | 400 | 5 | 131 - 48 | 1.200 - 9.600 |
| 2 - JMV 3-13T - D | 2.2 | 3 | 400 | 5 | 141 - 52 | 1.200 - 9.600 |
Série 5 (2 - JMV)
Note: Click on table rows to highlight and compare models.
| Model | kW | HP | V | Amp (A) | Head Pressure (m) | Flow Rate (l/h) |
|---|---|---|---|---|---|---|
| 2 - JMV 5-3M - D | 0.55 | 0.75 | 230 | 3.5 | 34 - 12 | 2.400 - 15.000 |
| 2 - JMV 5-4M - D | 0.75 | 1 | 230 | 4.4 | 45 - 15 | 2.400 - 15.000 |
| 2 - JMV 5-5M - D | 1.1 | 1.5 | 230 | 6.3 | 57 - 19 | 2.400 - 15.000 |
| 2 - JMV 5-6M - D | 1.1 | 1.5 | 230 | 6.3 | 68 - 23 | 2.400 - 15.000 |
| 2 - JMV 5-7M - D | 1.5 | 2 | 230 | 8.4 | 81 - 35 | 2.400 - 15.000 |
| 2 - JMV 5-3T - D | 0.55 | 0.75 | 400 | 1.4 | 34 - 12 | 2.400 - 15.000 |
| 2 - JMV 5-4T - D | 0.75 | 1 | 400 | 1.7 | 45 - 15 | 2.400 - 15.000 |
| 2 - JMV 5-5T - D | 1.1 | 1.5 | 400 | 2.4 | 57 - 19 | 2.400 - 15.000 |
| 2 - JMV 5-6T - D | 1.1 | 1.5 | 400 | 2.4 | 68 - 23 | 2.400 - 15.000 |
| 2 - JMV 5-7T - D | 1.5 | 2 | 400 | 3.2 | 81 - 35 | 2.400 - 15.000 |
| 2 - JMV 5-8T - D | 2.2 | 3 | 400 | 5 | 92 - 40 | 2.400 - 15.000 |
| 2 - JMV 5-9T - D | 2.2 | 3 | 400 | 5 | 104 - 45 | 2.400 - 15.000 |
| 2 - JMV 5-10T - D | 2.2 | 3 | 400 | 5 | 115 - 50 | 2.400 - 15.000 |
| 2 - JMV 5-11T - D | 2.2 | 3 | 400 | 5 | 127 - 55 | 2.400 - 15.000 |
| 2 - JMV 5-12T - D | 3 | 4 | 400 | 5.9 | 140 - 61 | 2.400 - 15.000 |
| 2 - JMV 5-13T - D | 3 | 4 | 400 | 5.9 | 152 - 66 | 2.400 - 15.000 |
Série 10 (2 - JMV)
Note: Click on table rows to highlight and compare models.
| Model | kW | HP | V | Amp (A) | Head Pressure (m) | Flow Rate (l/h) |
|---|---|---|---|---|---|---|
| 2 - JMV 10-2M - D | 0.75 | 1 | 230 | 4.4 | 23 - 1 | 2.400 - 30.000 |
| 2 - JMV 10-3M - D | 1.1 | 1.5 | 230 | 6.3 | 34 - 4 | 2.400 - 30.000 |
| 2 - JMV 10-4M - D | 1.5 | 2 | 230 | 8.4 | 44 - 9 | 2.400 - 30.000 |
| 2 - JMV 10-2T - D | 0.75 | 1 | 400 | 1.7 | 23 - 1 | 2.400 - 30.000 |
| 2 - JMV 10-3T - D | 1.1 | 1.5 | 400 | 2.4 | 34 - 4 | 2.400 - 30.000 |
| 2 - JMV 10-4T - D | 1.5 | 2 | 400 | 3.2 | 44 - 9 | 2.400 - 30.000 |
| 2 - JMV 10-5T - D | 2.2 | 3 | 400 | 5 | 60 - 15 | 2.400 - 30.000 |
| 2 - JMV 10-6T - D | 2.2 | 3 | 400 | 5 | 72 - 18 | 2.400 - 30.000 |
| 2 - JMV 10-7T - D | 3 | 4 | 400 | 5.9 | 84 - 21 | 2.400 - 30.000 |