High-performance MV multicellular electric pumps.

MV Multicellular Electric Pumps – Performance and Versatility. MV Multicellular Electric Pumps offer high performance in pumping clean liquids, with flow rates up to 15 m³/h and heads up to 160 m.

Applications

  • Industrial processes and liquid transfer.
  • Domestic water supply.
  • Hydraulic pressure systems
  • Water treatment
  • Agricultural irrigation
  • Sistemas de lavagem industrial

Technical Data

Type Multistage centrifugal pump
Standard In-line
Motor Details Hermetically sealed electric motor impregnated with protective resin
Voltage 220-230V (1~) / 380-415V (3~)
Max Flow 15 m³/h
Max Head 160 m
Protection IP 55
Insulation Class F
Operation S1 (Serviço Contínuo)

List of Materials
Pos. Description Material (Standard)
1 Tie rod Stainless Steel AISI 304 (1.4301)
2 Ring Stainless Steel AISI 304 (1.4301)
3 Coupling Cast iron
4 Stud Steel
5 Screw M6x10 Stainless Steel
6 Pin Stainless Steel AISI 304 (1.4301)
7 Shaft Stainless Steel AISI 304 (1.4301)
8 Coupling guard Stainless Steel AISI 304 (1.4301)
9 Motor coupling bracket Cast iron
10 Air vent Brass / Stainless steel
11 Screw M4x70 Stainless Steel
12 O-ring 124x4 NBR
13 Mechanical seal SiC / SiC
14 Seal spring guard Stainless Steel AISI 304 (1.4301)
15 Last-stage diffuser Noryl
16 Diffuser Noryl
17 Impeller Noryl
18 Diffuser cover Noryl
19 Outer jacket Stainless Steel AISI 304 (1.4301)
20 Female R/E M12 Stainless Steel AISI 304 (1.4301)
21 Shaft guide Stainless Steel AISI 304 (1.4301)
22 O-ring 14,54x2,62 NBR
23 Stainless steel plug 1/4 Stainless Steel AISI 304 (1.4301)
24 Ring Teflon
25 Base Cast iron
26 Screw M8x20 Stainless Steel
27 Plastic cover 1 1/4 Plastic
28 Plastic cover 1 Plastic
29 Shaft guide bushing Bronze / Graphite

  • A instalação deve ser efectuada por pessoal qualificado.
  • Assegurar que a tensão de alimentação é compatível com a tensão da rede.
  • Utilizar a bomba dentro dos limites constantes na placa de características.
  • Never run the pump dry. Not even for a short trial run.

Q–H performance chart. Each curve represents a model.

Select a model in the following table to highlight its corresponding curve. The table contains the same values as the chart.

Select a model to highlight its corresponding curve.

Scroll horizontally to view all values. The “Model” column remains visible.

Model Motor Details H (m) · Q (m³/h)
kWHPA (400V) 00.61.21.82.433.64.24.8
0,37 0,50 1,00 30,0 28,0 26,0 24,0 20,0 17,0 12,0 7,0
0,55 0,75 1,40 42,0 40,0 37,0 33,0 29,0 23,0 17,0 10,0
0,55 0,75 1,40 53,0 50,0 46,0 42,0 36,0 29,0 21,0 12,0
0,75 1,00 1,70 66,0 62,0 57,0 52,0 45,0 36,0 26,0 15,0
1,10 1,50 2,40 78,0 74,0 67,0 61,0 53,0 43,0 31,0 18,0
1,10 1,50 2,40 89,0 84,0 77,0 70,0 60,0 49,0 35,0 20,0
1,50 2,00 3,20 100,0 95,0 87,0 79,0 68,0 55,0 39,0 23,0
1,50 2,00 3,20 111,0 105,0 96,0 88,0 75,0 61,0 44,0 25,0
1,50 2,00 3,20 122,0 116,0 106,0 96,0 83,0 67,0 48,0 28,0
2,20 3,00 5,00 134,0 126,0 116,0 105,0 90,0 74,0 53,0 30,0
2,20 3,00 5,00 145,0 137,0 125,0 114,0 98,0 80,0 57,0 33,0
0,55 0,75 1,40 32,0 30,0 29,0 27,0 25,0 23,0 20,0 15,0 11,0
0,55 0,75 1,40 43,0 41,0 39,0 37,0 34,0 31,0 27,0 20,0 15,0
0,75 1,00 1,70 56,0 53,0 51,0 48,0 44,0 40,0 34,0 26,0 20,0
1,10 1,50 2,40 68,0 65,0 62,0 58,0 54,0 48,0 42,0 32,0 24,0
1,10 1,50 2,40 80,0 76,0 73,0 68,0 63,0 57,0 49,0 38,0 28,0
1,50 2,00 3,20 91,0 87,0 83,0 78,0 72,0 65,0 56,0 43,0 32,0
1,50 2,00 3,20 102,0 98,0 93,0 88,0 81,0 73,0 63,0 48,0 36,0
1,50 2,00 3,20 114,0 109,0 104,0 98,0 90,0 81,0 70,0 55,0 40,0
2,20 3,00 5,00 125,0 120,0 114,0 107,0 99,0 89,0 77,0 59,0 44,0
2,20 3,00 5,00 137,0 131,0 125,0 117,0 108,0 98,0 84,0 65,0 48,0
2,20 3,00 5,00 148,0 141,0 135,0 127,0 117,0 106,0 91,0 70,0 52,0

Q–H performance chart. Each curve represents a model.

Select a model in the following table to highlight its corresponding curve. The table contains the same values as the chart.

Select a model to highlight its corresponding curve.

Scroll horizontally to view all values. The “Model” column remains visible.

Model Motor Details H (m) · Q (m³/h)
kWHPA (400V) 01.22.43.64.85.466.67.510.812.615
0,55 0,75 1,40 37,0 34,0 31,0 29,0 25,0 23,0 20,0 17,0 12,0
0,75 1,00 1,70 49,0 45,0 41,0 38,0 33,0 30,0 27,0 23,0 15,0
1,10 1,50 2,40 61,0 57,0 52,0 48,0 42,0 38,0 33,0 28,0 19,0
1,10 1,50 2,40 73,0 68,0 62,0 57,0 50,0 45,0 40,0 34,0 23,0
1,50 2,00 3,20 85,0 81,0 76,0 71,0 64,0 59,0 54,0 47,0 35,0
2,20 3,00 5,00 98,0 92,0 86,0 82,0 74,0 67,0 62,0 54,0 40,0
2,20 3,00 5,00 110,0 104,0 97,0 92,0 83,0 76,0 69,0 60,0 45,0
2,20 3,00 5,00 122,0 115,0 108,0 102,0 92,0 84,0 77,0 67,0 50,0
2,20 3,00 5,00 134,0 127,0 119,0 112,0 101,0 92,0 85,0 74,0 55,0
3,00 4,00 5,90 149,0 140,0 132,0 124,0 112,0 102,0 94,0 82,0 61,0
3,00 4,00 5,90 161,0 152,0 143,0 135,0 121,0 111,0 102,0 88,0 66,0
0,75 1,00 1,70 24,0 23,0 22,0 21,0 19,0 18,0 17,0 16,0 13,0 8,0 5,0 1,0
1,10 1,50 2,40 36,0 34,0 31,0 32,0 30,0 29,0 28,0 27,0 24,0 18,0 12,0 4,0
1,50 2,00 3,20 46,0 44,0 42,0 41,0 39,0 38,0 38,0 37,0 34,0 24,0 18,0 9,0
2,20 3,00 5,00 62,0 60,0 57,0 55,0 53,0 52,0 51,0 50,0 46,0 36,0 28,0 15,0
2,20 3,00 5,00 74,0 72,0 68,0 66,0 64,0 62,0 61,0 60,0 55,0 43,0 34,0 18,0
3,00 4,00 5,90 86,0 84,0 79,0 77,0 75,0 72,0 71,0 70,0 64,0 50,0 40,0 21,0
Technical Support

Need support for this equipment?

For distributors, OEM/private-label programs, and technical buyers: share company, market, volume, and application details for a more precise commercial or technical response.

Request Proposal / Technical Support

Requests with company, market, and application details receive a faster business-day response.

Choose the option that best describes the commercial or technical request.

Include application, market, expected quantity or technical need in at least 80 characters.

Tech Sheet Compare