WFD Submersible Pump - Vortex and Double Channel

Submersible electric pumps for wastewater and drainage, available in Vortex and Bicanal versions.

The WFD series consists of submersible electric pumps designed for pumping wastewater and drainage. With options for Vortex impeller (for water with suspended solids) and Bicanal (for greater efficiency in less loaded water), these pumps offer versatility and robustness for domestic and industrial applications.

Applications

  • Drainage of wastewater and sewage.
  • Domestic, agricultural, and industrial use.
  • Emptying of pits and settling tanks.
  • Pumping of water with suspended solids (Vortex Models).

Technical Data

Type Vortex / Bicanal
Max Temperature 40 ºC
Protection IP 68
Insulation Class B
Electric cable length 10 m
Impeller Vortex / Bicanal (Cast Iron)
Discharge 1" 1/2 - 2" - 3"

Q–H performance chart. Each curve represents a model.

Select a model in the following table to highlight its corresponding curve. The table contains the same values as the chart.

Select a model to highlight its corresponding curve.

Scroll horizontally to view all values. The “Model” column remains visible.

Model Motor Details H (m) · Q (m³/h)
kWHPAmp (A) 061218243036424854
0,55 0,75 - 15,0 12,0 8,0
0,75 1,00 - 20,0 16,0 13,0 7,0
0,75 1,00 - 16,0 13,0 9,0
1,10 1,50 - 13,0 12,0 10,0 8,0 5,0
1,10 1,50 - 20,0 17,0 15,0 10,0
1,10 1,50 - 8,0 7,5 7,0 6,5 6,0 5,0 4,0 3,0
1,50 2,00 - 21,0 19,0 17,0 15,0 12,0
1,50 2,00 - 16,0 14,0 12,0 10,0 8,0 4,0
1,50 2,00 - 12,0 11,0 10,5 10,0 9,5 9,0 8,5 7,5 6,0 4,0
0,37 0,50 - 6,0 5,0 4,0
0,55 0,75 - 8,0 7,0 6,0 4,0
0,75 1,00 - 11,0 10,0 9,0 7,5 5,0
Technical Support

Need support for this equipment?

For distributors, OEM/private-label programs, and technical buyers: share company, market, volume, and application details for a more precise commercial or technical response.

Request Proposal / Technical Support

Requests with company, market, and application details receive a faster business-day response.

Choose the option that best describes the commercial or technical request.

Include application, market, expected quantity or technical need in at least 80 characters.

Tech Sheet Compare