DOUBLE HYDROPNEUMATIC CENTRAL WITH VARIABLE SPEED JMV-V VARIABLE SPEED

Automatic double hydropneumatic central with variable speed for constant pressure and efficiency.

JMV-V Double Hydropneumatic Power Units are equipped with state-of-the-art variable speed drives, allowing them to maintain constant pressure in the network with maximum energy efficiency. Consisting of two MV series electric pumps connected in parallel, the system manages cascade and alternating operation, ensuring redundancy, less wear and tear, and precise adaptation to large flow variations.

Applications

  • Hydropneumatic systems.
  • Water supply in domestic installations
  • Civil and industrial systems use
  • Industrial processes and pressurization systems.

Technical Data

Type Centrais Hidropneumáticas Automáticas Duplas
Series 2 - JMV-V (Série MV)
Control Variador de Velocidade (Inversor)
Components 2 Eletrobombas em paralelo
Protection Proteção integral (Sobrecarga, falta de água, sobretensão)
Cooling Cooled by pumped liquid

  • Hydropneumatic systems.
  • Water supply in domestic installations
  • Civil and industrial systems use
  • Industrial processes and pressurization systems.

Note: Click on table rows to highlight and compare models.

Model kW HP V Amp (A) Head Pressure (m) Flow Rate (l/h)
2 - JMV 2-4M - V 0.55 0.75 230 3.5 40 - 10 1.200 - 8.400
2 - JMV 2-5M - V 0.55 0.75 230 3.5 50 - 12 1.200 - 8.400
2 - JMV 2-6M - V 0.75 1 230 4.4 62 - 15 1.200 - 8.400
2 - JMV 2-7M - V 1.1 1.5 230 6.3 74 - 18 1.200 - 8.400
2 - JMV 2-8M - V 1.1 1.5 230 6.3 84 - 20 1.200 - 8.400
2 - JMV 2-9M - V 1.5 2 230 8.4 95 - 23 1.200 - 8.400
2 - JMV 2-10M - V 1.5 2 230 8.4 105 - 25 1.200 - 8.400
2 - JMV 2-11M - V 1.5 2 230 8.4 116 - 28 1.200 - 8.400
2 - JMV 2-4T - V 0.55 0.75 400 1.4 40 - 10 1.200 - 8.400
2 - JMV 2-5T - V 0.55 0.75 400 1.4 50 - 12 1.200 - 8.400
2 - JMV 2-6T - V 0.75 1 400 1.7 62 - 15 1.200 - 8.400
2 - JMV 2-7T - V 1.1 1.5 400 2.4 74 - 18 1.200 - 8.400
2 - JMV 2-8T - V 1.1 1.5 400 2.4 84 - 20 1.200 - 8.400
2 - JMV 2-9T - V 1.5 2 400 3.2 95 - 23 1.200 - 8.400
2 - JMV 2-10T - V 1.5 2 400 3.2 105 - 25 1.200 - 8.400
2 - JMV 2-11T - V 1.5 2 400 3.2 116 - 28 1.200 - 8.400
2 - JMV 2-12T - V 2.2 3 400 5 126 - 30 1.200 - 8.400
2 - JMV 2-13T - V 2.2 3 400 5 137 - 33 1.200 - 8.400

Note: Click on table rows to highlight and compare models.

Model kW HP V Amp (A) Head Pressure (m) Flow Rate (l/h)
2 - JMV 3-3M - V 0.55 0.75 230 3.5 30 - 11 1.200 - 9.600
2 - JMV 3-4M - V 0.55 0.75 230 3.5 41 - 15 1.200 - 9.600
2 - JMV 3-5M - V 0.75 1 230 4.4 53 - 20 1.200 - 9.600
2 - JMV 3-6M - V 1.1 1.5 230 6.3 65 - 24 1.200 - 9.600
2 - JMV 3-7M - V 1.1 1.5 230 6.3 76 - 28 1.200 - 9.600
2 - JMV 3-8M - V 1.5 2 230 8.4 87 - 32 1.200 - 9.600
2 - JMV 3-9M - V 1.5 2 230 8.4 98 - 36 1.200 - 9.600
2 - JMV 3-10M - V 1.5 2 230 8.4 62 - 17 1.200 - 8.400
2 - JMV 3-3T - V 0.55 0.75 400 1.4 30 - 11 1.200 - 9.600
2 - JMV 3-4T - V 0.55 0.75 400 1.4 41 - 15 1.200 - 9.600
2 - JMV 3-5T - V 0.75 1 400 1.7 53 - 20 1.200 - 9.600
2 - JMV 3-6T - V 1.1 1.5 400 2.4 65 - 24 1.200 - 9.600
2 - JMV 3-7T - V 1.1 1.5 400 2.4 76 - 28 1.200 - 9.600
2 - JMV 3-8T - V 1.5 2 400 3.2 87 - 32 1.200 - 9.600
2 - JMV 3-9T - V 1.5 2 400 3.2 98 - 36 1.200 - 9.600
2 - JMV 3-10T - V 1.5 2 400 3.2 62 - 17 1.200 - 8.400
2 - JMV 3-11T - V 2.2 3 400 5 120 - 44 1.200 - 9.600
2 - JMV 3-12T - V 2.2 3 400 5 131 - 48 1.200 - 9.600
2 - JMV 3-13T - V 2.2 3 400 5 141 - 52 1.200 - 9.600

Note: Click on table rows to highlight and compare models.

Model kW HP V Amp (A) Head Pressure (m) Flow Rate (l/h)
2 - JMV 5-3M - V 0.55 0.75 230 3.5 34 - 12 2.400 - 15.000
2 - JMV 5-4M - V 0.75 1 230 4.4 45 - 15 2.400 - 15.000
2 - JMV 5-5M - V 1.1 1.5 230 6.3 57 - 19 2.400 - 15.000
2 - JMV 5-6M - V 1.1 1.5 230 6.3 68 - 23 2.400 - 15.000
2 - JMV 5-7M - V 1.5 2 230 8.4 81 - 35 2.400 - 15.000
2 - JMV 5-3T - V 0.55 0.75 400 1.4 34 - 12 2.400 - 15.000
2 - JMV 5-4T - V 0.75 1 400 1.7 45 - 15 2.400 - 15.000
2 - JMV 5-5T - V 1.1 1.5 400 2.4 57 - 19 2.400 - 15.000
2 - JMV 5-6T - V 1.1 1.5 400 2.4 68 - 23 2.400 - 15.000
2 - JMV 5-7T - V 1.5 2 400 3.2 81 - 35 2.400 - 15.000
2 - JMV 5-8T - V 2.2 3 400 5 92 - 40 2.400 - 15.000
2 - JMV 5-9T - V 2.2 3 400 5 104 - 45 2.400 - 15.000
2 - JMV 5-10T - V 2.2 3 400 5 115 - 50 2.400 - 15.000
2 - JMV 5-11T - V 2.2 3 400 5 127 - 55 2.400 - 15.000
2 - JMV 5-12T - V 3 4 400 5.9 140 - 61 2.400 - 15.000
2 - JMV 5-13T - V 3 4 400 5.9 152 - 66 2.400 - 15.000

Note: Click on table rows to highlight and compare models.

Model kW HP V Amp (A) Head Pressure (m) Flow Rate (l/h)
2 - JMV 10-2M - V 0.75 1 230 4.4 23 - 1 2.400 - 30.000
2 - JMV 10-3M - V 1.1 1.5 230 6.3 34 - 4 2.400 - 30.000
2 - JMV 10-4M - V 1.5 2 230 8.4 44 - 9 2.400 - 30.000
2 - JMV 10-2T - V 0.75 1 400 1.7 23 - 1 2.400 - 30.000
2 - JMV 10-3T - V 1.1 1.5 400 2.4 34 - 4 2.400 - 30.000
2 - JMV 10-4T - V 1.5 2 400 3.2 44 - 9 2.400 - 30.000
2 - JMV 10-5T - V 2.2 3 400 5 60 - 15 2.400 - 30.000
2 - JMV 10-6T - V 2.2 3 400 5 72 - 18 2.400 - 30.000
2 - JMV 10-7T - V 3 4 400 5.9 84 - 21 2.400 - 30.000
Technical Support

Need support for this equipment?

Select the purpose of your request and share the main project details. Our sales or technical team will reply with a proposal, technical information, compatibility guidance, or help choosing the right solution.

Request Proposal / Technical Support

Guided form · response within 24 business hours

Choose the closest option so we can reply faster and with more relevant information.

Request Proposal Call
WhatsApp